PALADIN | Positron Annihilation Detection Beyond the Limits

Summary
Given the growth and aging of the world population, innovative solutions for sustainable energy and health are needed. Novel technologies play an enabling role in the realization of such solutions. Better devices for the detection of annihilation quanta resulting from positron annihilation are an example. In material science these detectors are needed for research on renewable energies and innovative energy storage using Positron Annihilation Lifetime Spectroscopy (PALS). In medicine they are required for diagnosis, staging, and treatment monitoring of diseases using Time-of-Flight Positron Emission Tomography (TOF-PET).
In both fields time resolution is a key parameter. Sub-100 picosecond resolution is needed but not yet available. Improvement of time resolution, however, must not deteriorate other performance parameters. This project aims to overcome present physical limits. Monolithic scintillation crystals will be read out with digital photon counter (DPC) arrays coupled to each of its surfaces. Innovative data processing methods will be developed to eliminate the influence of scintillation photon propagation, currently the major bottleneck in large scintillation crystals that are nevertheless needed for high detection efficiency. We aim at coincidence resolving times (CRT) < 100ps FWHM, 10% energy resolution, 1 mm isotropic spatial resolution, and 90% detection efficiency.
The detector will be incorporated in a PALS setup. After the performance has been characterized, it will be used for TU Delft’s materials research on renewable energy. The detector characterization will also serve as a proof-of-concept for application in clinical TOF-PET devices. The results are furthermore expected to be of relevance to fields such as high-energy physics.
To investigate options for further improvement of the already unprecedented time resolution, studies will be done towards exploiting the Cherenkov-effect in a detector based on a hybrid Cherenkov/scintillation material.
Unfold all
/
Fold all
More information & hyperlinks
Web resources: https://cordis.europa.eu/project/id/659317
Start date: 01-09-2015
End date: 30-11-2017
Total budget - Public funding: 165 598,80 Euro - 165 598,00 Euro
Cordis data

Original description

Given the growth and aging of the world population, innovative solutions for sustainable energy and health are needed. Novel technologies play an enabling role in the realization of such solutions. Better devices for the detection of annihilation quanta resulting from positron annihilation are an example. In material science these detectors are needed for research on renewable energies and innovative energy storage using Positron Annihilation Lifetime Spectroscopy (PALS). In medicine they are required for diagnosis, staging, and treatment monitoring of diseases using Time-of-Flight Positron Emission Tomography (TOF-PET).
In both fields time resolution is a key parameter. Sub-100 picosecond resolution is needed but not yet available. Improvement of time resolution, however, must not deteriorate other performance parameters. This project aims to overcome present physical limits. Monolithic scintillation crystals will be read out with digital photon counter (DPC) arrays coupled to each of its surfaces. Innovative data processing methods will be developed to eliminate the influence of scintillation photon propagation, currently the major bottleneck in large scintillation crystals that are nevertheless needed for high detection efficiency. We aim at coincidence resolving times (CRT) < 100ps FWHM, 10% energy resolution, 1 mm isotropic spatial resolution, and 90% detection efficiency.
The detector will be incorporated in a PALS setup. After the performance has been characterized, it will be used for TU Delft’s materials research on renewable energy. The detector characterization will also serve as a proof-of-concept for application in clinical TOF-PET devices. The results are furthermore expected to be of relevance to fields such as high-energy physics.
To investigate options for further improvement of the already unprecedented time resolution, studies will be done towards exploiting the Cherenkov-effect in a detector based on a hybrid Cherenkov/scintillation material.

Status

CLOSED

Call topic

MSCA-IF-2014-EF

Update Date

28-04-2024
Geographical location(s)
Structured mapping
Unfold all
/
Fold all
EU-Programme-Call
Horizon 2020
H2020-EU.1. EXCELLENT SCIENCE
H2020-EU.1.3. EXCELLENT SCIENCE - Marie Skłodowska-Curie Actions (MSCA)
H2020-EU.1.3.2. Nurturing excellence by means of cross-border and cross-sector mobility
H2020-MSCA-IF-2014
MSCA-IF-2014-EF Marie Skłodowska-Curie Individual Fellowships (IF-EF)